Abstract

Problems involved in the determination of Au and the platinum group elements by the nickel sulphide fire assay (NiS-FA) procedure for black shale samples, samples containing magnetite, and samples containing As, Cu, and Fe were studied. The interference of the graphite in black shale samples was eliminated either by roasting the sample prior to fusion or by adding an oxidant to the fusion flux. Addition of a reducing agent to samples, containing the oxygen-rich mineral magnetite, enabled the NiS-FA procedure to be carried out for this sample type. The interference of Cu on Rh in the ICP-MS determination was corrected by establishing a linear correlation between the interference of Cu on 103Rh and 105Pd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.