Abstract
In this paper, gas permeability of high performance concrete (HPC) with water-binder ratio (w/b) varying from 0.25 to 0.35 and level of fly ash (FA) replacement ranging from 0% to 60%, were determined. Pore structure of high performance concrete was also investigated with mercury intrusion porosimetry (MIP). It showed that w/b ratio was found to have a varying influence on gas permeability. In this research, it achieved higher gas permeability at w/b of 0.30 than that at w/b of 0.25 or 0.35. The incorporation of fly ash increased the gas permeability of HPC. There’s a better interdependence between gas permeability and porosity than that between gas permeability and threshold diameter and mean diameter, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.