Abstract
A simple method of detection was developed for gamma-hydroxybutyrate (GHB). The method involves the derivatization of GHB using a hexyl-chloroformate procedure in aqueous media (such as water or urine), extraction of the derivatization product directly from the sample using solid-phase microextraction, and subsequent separation and detection with gas chromatography quadrupole ion trap mass spectrometry. The deuterated form of GHB (GHB-D6) is used as an internal standard for quantitation. The method was linear for GHB-spiked pure water samples from 2 to 150 microg/mL GHB with a detection limit of 0.2 microg/mL. Spiked urine samples showed linearity from 5 to 500 microg/mL GHB with a detection limit of 2 microg/mL. The SPME-GC/MS method is applied to actual case samples, and the results are compared to those values obtained using a conventional GC/MS method. Sensitivity and linearity are comparable to those seen using traditional methods of separation, yet the SPME method is superior due to the simplicity, speed of analysis, reduction in solvent waste, and ability to differentiate between GHB and gamma-butyrolactone (GBL).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.