Abstract

Furfural is a sensitive indicator of beer staling. A new solid-phase extraction (SPE) column PEP-SPE (Polar-Enhanced Polymer, 500 mg/6 mL) was used to develop a method for extraction of furfural from beer. The PEP-SPE column retains furfural with higher selectivity than the commonly used C 18 -SPE column. Satisfactory precisions were obtained with %RSD (n = 6) less than 2.2% for peak areas. Recovery rates were in the range of 99.7-100.1% due to the simple treatment and good resolution. The detection limit was 5 μg/L. Furfural concentration ranged from 10 to 32 μg/L in twelve fresh beer samples. A noticeable increase in furfural content was found after beer samples were kept at 35°C for seven days. The calculated correlation coefficient between taste panel scores for beer freshness and the furfural content of aged beer samples was -0.65, which showed a good inverse correlation between freshness marks and furfural content.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.