Abstract

An analytical method was elaborated for simultaneous extraction and determination of fluorinated anionic and non-ionic surfactants in sewage sludge. Surfactant compounds were determined by liquid chromatography–mass spectrometry (LC–MS) after Soxhlet extraction, hot steam extraction and pressurised liquid extraction (PLE) using spiked sludge samples. PLE in a multiple-step procedure consisting of sequential use of ethyl acetate–dimethylformamide and methanol–phosphoric acid resulted in the most efficient extraction procedure. Quantitative analyses of the fluorinated anionic perfluorooctanesulfonate (PFOS) and the partly fluorinated non-ionic alkylpolyglycol ether (FAEO) surfactants were performed by selected ion monitoring LC–MS. Electrospray ionisation or atmospheric pressure chemical ionisation in negative or positive mode was performed. Recoveries between 105 and 120% could be reached. No PFOS and non-ionic FAEO surfactants in concentrations higher than 6 or 10 mg kg −1 dry matter were observed in real environmental samples. Therefore aerobic and anaerobic biodegradation was performed to investigate the fate of fluorinated surfactants reaching wastewaters. Biological wastewater treatment in laboratory scale under aerobic or anaerobic conditions led to an elimination by biodegradation.