Abstract

A method involving solid-phase extraction (SPE) and reversed-phase liquid chromatography-mass spectrometry (LC-MS) has been developed for determination, in groundwater, of nitrobenzoic acids associated with 2,4,6-trinitrotoluene production. Pre-concentration on a co-polymer-based SPE cartridge enabled quantitative extraction of the analytes from water. Investigation of negative ion electrospray and atmospheric-pressure chemical ionization mass spectrometry indicated the sensitivity of APCI was more than twice that of ESI. An 15N-labeled internal standard was used to achieve more accurate quantitation and mass assignment. Recovery was better than 80% when 10 mL water was extracted with the SPE cartridge. Combination of SPE with LC-MS analysis resulted in method detection limits of less than 5 microg L-1. The method has been used for analysis of groundwater samples collected from a site of a former ammunition plant. Contamination with nitrobenzoic acids was determined at microg L-1 levels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.