A solid-phase extraction (SPE) method based on conductive polypyrrole (PPy) nanofibers which were fabricated by electrospinning and in situ polymerization was developed. PPy nanofibers-mediated SPE followed by high performance liquid chromatography (HPLC) was used for the determination of three synthetic estrogens, namely diethylstilbestrol (DES), dienestrol (DIS), or hexestrol (HS) in milk sample. Extraction conditions including extraction nanofibers, donor solution pH and salt concentration were optimized. The target compounds were extracted from a 0.5 mL aqueous sample at pH 5.0 through PPy fibers, and then were eluted with 0.1 mL methanol. After extraction, the eluant was directly injected into an HPLC system for detection. Under the optimized extraction conditions, a large enrichment factor was achieved for three estrogens. The limit of detection (LOD) at a signal to noise ratio (S/N) of 3 ranged from 0.02 to 0.05 µg mL-1 for the estrogens in milk sample.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.