Abstract

In this paper a study on the use of insulation resistance of power transformer windings as a diagnostic factor for determining the lifetime line parameters of their insulation is presented. Accelerated thermal aging was carried out for plane winding models at 115, 5 and 155°C, for 1200 … 7000 h. For some values of the aging duration $\tau $, the reported values of the insulation resistance $R_{i(\tau)}$ were determined, and for two values of the end-of-life criterion $R_{i,eol}$, the lifetime lines corresponding to the Dakin and Montsinger aging models were drawn A new method for determining parameters a and b (by measuring three values of the windings insulation resistance) and calculating the consumed and remaining lifetimes is proposed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.