Abstract

In an effort to measure electron-impact ionization (EII) cross-sections of He-like Fe24+ at the electron beam ion trap (EBIT) facility of the National Institute of Standards and Technology (NIST), we have experimentally determined the corrections to the nominal beam energy determined by the voltages applied to the EBIT. High-resolution X-ray spectra were recorded at nominal electron beam energies between 6660 eV and 6750 eV using X-ray microcalorimetry based upon an array of 192 transition-edge sensors (TES). A large-scale collisional-radiative simulation of the non-Maxwellian EBIT plasma using relevant atomic data calculated with Flexible Atomic Code allowed us to determine the space-charge correction due to the electron beam including the neutralization factor by the ion cloud of the EBIT.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.