Abstract

A high-performance liquid chromatography with electrochemical detection (HPLC-ECD) system was developed for the simultaneous determination of eicosapentaenoic acid (EPA), docosahexaenoic acid (DHA), and arachidonic acid (AA) in human plasma. In the present HPLC-ECD system, EPA, DHA, and AA were separated using a reverse-phase C30 column and detected based on the voltammetric reduction of 3,5-di-tert-butyl-1,2-benzoquinone (DBBQ). Chromatographic peak areas were proportional to the concentration of EPA, DHA, and AA from 0.75 μM to 0.1 mM (r > 0.998). The concentrations of EPA, DHA, and AA in plasma from healthy human subjects after overnight fasting were determined, and the ratio of EPA to AA was obtained by the present HPLC-ECD method, which required 40 μL of human plasma and a simple procedure of sample preparation using diethyl ether extraction. Moreover, changes in EPA, DHA, and AA concentrations in a human subject were monitored before and after fish oil supplement administration by the present HPLC-ECD system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.