Abstract

Here, a new method for simultaneous determination of diffusion coefficient D and interfacial mass transfer coefficient (or convective mass transfer coefficient) k was proposed for bovine serum albumin (BSA) adsorption into porous polymeric membranes. The experimental data for BSA concentration at different membrane depth and different time were determined from FTIR-mapping measurements. Then the diffusion coefficient D and interfacial mass transfer coefficient k were estimated from the calculated dimensionless concentration data at different time and membrane depth by a trial-and-error method based on the diffusion equation initiated in this paper. The diffusion coefficient D and interfacial mass transfer coefficient k evaluated in this manner are respectively: D = 1.56 ± 0.01 × 10 - 12 m 2 / s and k = 4.3 ± 0.1 × 10 - 9 m / s . The theoretical concentration values calculated from the determined parameters were compared with experimental reading from FTIR mappings, which showed a good agreement between them, especially for the case of a relatively long-time adsorption.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.