Abstract

This research was aimed at determining the meter accuracy degradation profiles and rates and testing them with the optimal consumption patterns using the comparative billing analysis methodology for 2 meter models (Model 1 and Model 2) of volumetric type and one model (Model 3) of velocity type of size 15 mm which are the most dominant in the Kampala water distribution system (KWDS), Uganda, by applying statistics. The meter accuracy degradation rates were determined as 6.67% per year for Model 1, 4.68% per year for Model 2, and 1.45% per year for Model 3 meters. Annual water losses due to meter inaccuracies were 24.1 m 3 for Model 1, 16.9 m 3 for Model 2, and 5.3 m 3 for Model 3, totaling to US$1.5 million every year. This study recommends that degradation rates are used to determine the optimal meter replacement period, and Model 3 meters are the most suitable meters for the KWDS.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.