Abstract

Adsorption of 10 PCB congeners in aqueous solutions on glass-fibre filters taken from different boxes but of the same type were not significantly different. The standard deviations using filters from the same box were below 10% at concentration levels of 4.1 ng L−1. At this level, the adsorption of dissolved PCB at the filters was in the range of 5–20% depending on the congener. This led to a procedure for determination of dissolved and particle-bound congener in authentic landfill leachate, which included correction for adsorption losses. The procedure was based on filtration through glass-fibre filters, followed by trapping of the PCB in the eluate on solid-phase extraction (SPE) disks. After separate supercritical fluid (SFE) extractions, with carbon dioxide, of the filters as well as of the SPE disks, the extracts were analysed on a two-column capillary GC-ECD system. Corrections for congener adsorption on glass-fibre filters were made, from which corrected distribution constants between particle-bound and dissolved PCB congener in the water phase could be obtained for authentic landfill leachate. These values (104–105) agreed well with those obtained by others.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call