Abstract

AbstractA method is described to determine cyclic fatty acids in cyclic monomers by gas‐liquid chromatography (GLC), which separates saturated straight‐chain esters from cyclic esters. The content of cyclic esters can be determined by integration of the area on the chromatograph under the cyclic peaks. GLC was applied to cyclic monomers made from linseed oil and from linolenic acid. Samples of both hydrogenated and nonhydrogenated cyclic monomers were analyzed; however, more reliable results were obtained on the hydrogenated samples. The results show a standard deviation of 0.25 for linseed oil and 0.36 for linolenic acid.Accuracy of the analysis was established by comparing data with that obtained by crystallization. The GLC method is approximately three times faster.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.