Abstract

In this study, the current density requirements of zinc sacrificial anode for corrosion protection of AA5083-H321 aluminum hull for the ship was determined through various electrochemical tests. Surface observation and chemical composition analysis were performed after the galvanostatic test for various current density requirements determined by the cathodic polarization experiment. As a result, the most appropriate current density requirement range was determined as 3.7 × 10−6–5.8 × 10−6 A/cm2. Excessive current density over 7.6 × 10−6 A/cm2 caused local surface damage due to the effect of Mg-rich and Fe-rich intermetallic phases. In addition, the self-consumption of zinc sacrificial anode was determined through Tafel's extrapolation method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.