Abstract

Clenbuterol is present in animal tissues and organs and, therefore, potentially present in gelatin derived from animal sources. The objective of this study was to develop a method for identify an quantify traces of clenbuterol in gelatin and jellies. The clenbuterol calibration curve showed linearity in the range of 20–1000 pg mL−1. The detection and quantification limits were 5 pg g−1 and 10 pg g−1, respectively. The recovery of the analyte ranged from 93.4 to 98.7% with an intra-day RSD% (n = 4) of 1.25%-3.25%, and an inter-day RSD% (n = 12) of 0.5%-2.25%, with good linearity (R2 = 0.99). The method developed and validated was successfully applied in 54 gelatin samples, 57.4% of which showed clenbuterol. This UHPLC-MS/MS method combines high sensitivity with good selectivity and short chromatographic run time.