A simplified wet-ashing technique is described for the determination of chelated iron in the urine, with special reference to DTPA-bound iron. The procedure dispenses with the need for quantitative transfer, and gives corresponding economy in time, labour, and glassware without loss of precision. The standard error of the mean estimate of a triplicate determination, using four reference standards, is +/- 4 mug/100 ml; precision may be further increased by the use of a calibration curve based on many standards.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.