Abstract
The reaction of the cationic dye, crystal violet (CV) with the anionic polyelectrolytes such as potassium poly (vinyl sulfate) (PVSK) results in a decrease of the absorbance of CV at the maximum absorption wavelength (590 nm). This change of the absorption spectra of the CV has been already applied to the determination of anionic polyelectrolytes using flow injection analysis method. In this paper, CV was applied to the indicator for the determination of cationic polyelectrolytes such as poly (diallyldimethylammonium chloride) (Cat-floc) by photometric titration, using a PVSK solution as a titrant. The end-point of the titration is detected as the break point of the titration curve. A linear relationship between the concentration of cationic polyelectrolyte and the end-point volume of the titrant exists in the concentration range from 0 to 5×10 −5 eq. mol dm −3 for Cat-floc, glycol chitosan and methylglycol chitosan. The effects of the concentration of CV and coexisting electrolytes in the sample solution and the effect of pH of the sample solution on the degree of the change of absorbance at the end-point were also examined.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.