Abstract

It is a common construction method to pour arch concrete in arch centering. The deformation law of arch centering was analyzed in process of pouring arch concrete, a new method to determine concrete cast-in-situ section lengths and corresponding formulas which based on deformation scale of arch centering were presented. According to influence line of arch centering deflection, a program used to calculate cast lengths and arch centering deformations was developed. This program could automatically calculate each segment of arch concrete based on the assigned deformation conditions. A numerical result shows that when the arch centering deformation scale was taken as the target, deformation proportion caused by each segment of concrete should be controlled on 0.5-0.6.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.