Abstract

Auto-PEEP, or PEEPi, occurs when alveolar pressure fails to decrease to zero at the end of exhalation. While PEEPi can be measured in paralyzed or apneic patients by occlusion of the ventilator expiratory valve at end-exhalation (PEEPi-OC), this may not be possible in patients with spontaneous respiratory efforts. When adjusting the ventilator PEEP valve, FRC increases only after PEEPi has been exceeded. In both mechanically ventilated and spontaneously breathing patients, changes in FRC are mirrored by changes in end-expiratory TGV as measured with RIP set in the DC mode. We compared PEEPi as measured by RIP to PEEPi-OC in 20 patients receiving mechanical ventilator support. Noninvasive measurement of changes in end-expiratory TGV by RIP is a convenient alternative method to estimate PEEPi in both controlled, assisted, and spontaneously ventilating patients.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.