Abstract

Objective To establish HPLC-DAD method for determination of 2 components in Baqia-sanyu granules. Methods The HPLC system consisted of the Fortis Cortecstm C18 column (4.6 mm × 250 mm, 5 μm), the mobile phase consisted of 0.05%KH2PO4 and acetonitrile, gradient elution flow rate was 1.0 ml/min, the column temperature was 30 ℃, and the UV detector was set at 290 nm. Results The linear response range of astilbin and engelitin were 0.002 2-0.044 μg and 0.012 4-0.248 μg(r=0.999 9). The average recovery were 97.0% and 97.8%. RSD were 1.61% and 1.65%. Conclusions The method high sensitive, accurate, repeatable and high specifid. It could be an important method to control the standard of this preparations. Key words: Chromatography, high pressure liquid; Astilbin; Engelitin; Baqia-sanyu Granule

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.