Abstract
Background: Workplace drug testing primarily relies on urine analysis, targeting multiple compounds with varying physicochemical characteristics. Biocompatible solid-phase microextraction (BioSPME) is a miniaturized solid-phase extraction technique that enables the simultaneous extraction and preconcentration of analytes directly from the biological matrix. Methods: The BioSPME procedure consisted of the sequential extraction of 50-μl urine samples using LC Tips C18 in basic and acidic pH, followed by desorption with methanol and n-hexane, respectively. The extracts were analyzed by ultra-performance LC-MS/MS. Results: Intra-day precision was 1.2-8.6% and inter-day precision was 1.8-14.2%. Accuracy was 96.8-107.4%. The extraction yields were 62.8-109.4%. The matrix effects were -3.98% to 1%. Conclusion: BioSPME shows promise as an alternative method for preparing urine samples prior to drug measurement by ultra-performance LC-MS/MS.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.