Abstract

In this work, an ordered mesoporous carbon (OMC)/Nafion coated fiber for solid-phase microextraction (SPME) was prepared and used as the working electrode for electro-enhanced SPME (EE-SPME) of amphetamines. The EE-SPME strategy is primarily based on the electro-migration and complementary charge interaction between fiber coating and ionic compounds. Compared with traditional SPME, EE-SPME exhibited excellent extraction efficiency for amphetamine (AP) and methamphetamine (MA) with an enhancement factor of 7.8 and 12.1, respectively. The present strategy exhibited good linearity for the determination of AP and MA in urine samples in the range of 10-1000ngmL(-1) and 20-1000ngmL(-1), respectively. The detection limits were found to be 1.2ngmL(-1) for AP and 4.8ngmL(-1) for MA. The relative standard deviations were calculated to be 6.2% and 8.5% for AP and MA, respectively. Moreover, the practical application of the proposed method was demonstrated by analyzing the amphetamines in urine and serum samples with satisfactory results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.