High sensitive rapid gas chromatography-mass spectrometry method for the determination of four carcinogenic alkyl methanesulfonates viz. methyl methanesulfonate, ethyl methanesulfonate, isopropyl methanesulfonate and n-butyl methanesulfonate in doxazosin mesylate has been presented by using selective ion monitoring mode. The optimum separation was achieved between methyl methanesulfonate, ethyl methanesulfonate, isopropyl methanesulfonate and n-butyl methanesulfonate on a DB-5 (30 m×0.32 mm×1.0 μm) capillary column under programming temperature. Acetonitrile, water and ammonia (90:9:1 v/v/v) mixture was used as diluent. Various factors involved in the gas chromatography-mass spectrometry method development are also presented. This method was validated as per International Conference on Harmonization guidelines. The limit of quantitation of methyl methanesulfonate, ethyl methanesulfonate, isopropyl methanesulfonate and n-butyl methanesulfonate is 6 ppm with respect to 30 mg/ml of doxazosin mesylate.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.