Abstract

A simple and sensitive column-switching high-performance liquid chromatographic (HPLC) method with fluorescence detection is described for the quantification of perospirone, a serotonin and dopamine antagonist, and its metabolite ID-15036 in human plasma. The test compounds were extracted from 2 ml of plasma using chloroform–hexane (30:70, v/v) and the extract was injected into a column I (TSK-PW precolumn, 10 μm, 35×4.6 mm I.D.) for clean-up and column II (C 18 STR ODS-II analytical column, 5 μm, 150×4.6 mm I.D.) for separation. The peak was detected using a fluorescence detector set at Ex 315 nm and Em 405 nm, and the total time for a chromatographic separation was ∼30 min. The method was validated for the concentration range from 0.1 to 100 ng/ml. Mean recoveries were 97% for perospirone and 96% for ID-15036. Intra- and inter-day relative standard deviations were less than 2.8 and 5.3% for perospirone and 2.4 and 4.4% for ID-15036, respectively, at the concentration range from 0.3 to 30 ng/ml. This method shows good specificity with respect to commonly prescribed psychotropic drugs, and it could be successfully applied for pharmacokinetic studies and therapeutic drug monitoring.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.