A rapid and simple methodology based on purge and trap with gas-chromatography coupled to triple quadrupole mass spectrometry has been developed for the analysis of 19 volatile organic compounds (VOCs) in wastewater (WW) effluents from four different treatments. The determination was carried out in the raw WW effluents, which were not submitted to any pre-treatment (e.g., filtration). A matrix effect study was also performed, concluding that solvent calibration was adequate to quantify VOCs in WW effluent samples containing a variety of suspended particulate matter. Adequate validation parameters were obtained with recovery values in the range 73-124% and precision values lower than 24%. Limits of quantification were established at 0.1 μg L(-1) for all VOCs. The proposed method was applied to the analysis of WW samples, detecting chloroform and toluene at concentrations ranging from 0.1 to 4.80 μg L(-1).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.