Abstract

The paper describes a simple and quantitative method for monitoring non-conjugated 17 beta-estradiol (E2) and its metabolites estrone (E1) and estriol (E3) as environmental contaminants in municipal sewage effluents. Estrogens were preconcentrated and cleaned up by solid-phase extraction using a reversed-phase C18 cartridge. They were derivatized with pentafluoropropionic acid anhydride, and the products were analyzed by gas chromatography/mass spectrometry. Recoveries from spiked distilled water and sewage were better than 87% at fortification levels of 100 and 20 ng/L. For a 1 L sewage sample and a concentration factor of 5000, detection limits were 5 ng/L for E1 and E2 and 10 ng/L for E3. In a brief survey of Canadian wastewater, these estrogens were detected in many raw sewage and effluent samples at concentrations ranging from 6 to 109 ng/L for E1, from < 5 to 15 ng/L for E2, and from < 10 to 250 ng/L for E3.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.