Abstract

A method is described for measuring the stable isotopic enrichment of taurine in cat urine samples by high resolution fast-atom bombardment mass spectrometry, after 15N labelled taurine was given to cats for the purpose of investigating taurine metabolism. The 15N enrichment of taurine was measured after hydrolysis and purification of taurine by anion/cation exchange chromatography. The isotopic ratio of taurine was determined by measuring the [M+H]+ ion peaks in the spectra of the unlabelled and labelled compounds under multiple ion scan conditions. The overall standard deviation of the measurement is better than 4%. This method requires no derivation and uses only 500 microL of urine samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.