Abstract

Carbamates are used in broad-spectrum insecticides and herbicides, and have highly efficient, low-residue, and long-lasting characteristics. However, this type of pesticide exerts mutagenic, teratogenic, carcinogenic, and other adverse effects, and its frequent use can exceed the recommended scope and limits. Research on the determination of carbamate pesticides mainly focuses on foods of plant origin and pays less attention to foods of animal origin. The methods for carbamate determination described in the current national standards have complicated operating procedures and low efficiency. Therefore, highly efficient and accurate methods for carbamate detection in milk must be established. In this work, a rapid method based on pass-through solid-phase extraction (SPE) purification coupled with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of 10 carbamate pesticides in liquid milk. The pretreatment and instrument methods were systematically optimized. The milk sample was extracted with acetonitrile, and then purified using a Captiva EMR-Lipid filtration kit. The purified extract was separated on an ACQUITY UPLC BEH C18 column with mobile phase of methanol and 0.1% formic acid aqueous solution in gradient elution. The flow rate was 0.3 mL/min. Column temperature was 35 ℃. Quantitative analysis was performed using the external standard method with matrix matching curves. The 10 carbamate pesticides showed good linear relationships in the mass concentration range of 2-200 μg/L, with correlation coefficients greater than 0.999. The limits of detection (LODs) and quantification (LOQs) for the 10 carbamate pesticides were 0.045-0.23 and 0.15-0.77 μg/kg, respectively. Recovery tests were conducted using the blank-matrix method at three spiked levels of 15, 50, and 100 μg/kg, and good recoveries for the 10 carbamate pesticides were obtained. In particular, the recoveries for the three spiked levels of 15, 50, and 100 μg/kg were 68.7%-93.3% with relative standard deviations (RSDs) of 1.8%-8.0%. The proposed method is efficient, convenient, accurate, and suitable for the rapid detection of the 10 carbamate pesticides in liquid milk. Compared with the conventional NH2 and ENVITM-18 SPE columns used in the national standard determination method, the proposed method demonstrated better purification effects. The recoveries for aldicarb sulfoxide, aldicarb sulfone, methomyl, and carbaryl after purification using the Captiva EMR-Lipid kit increased from 60% to 80%. Thus, the proposed method is suitable for targets with strong polarity and gives measurement results with good repeatability and accuracy.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call