Abstract
A graphite furnace atomic absorption spectrometry (GFAAS) method for cadmium determination in Chinese herbal medicines was prepared. In this study, 2% (NH4)2HPO4 was used as matrix modifier, which could enhance the ashing temperature and eliminate the matrix interference.Cadmium has been determined using GFAAS method with deuterium background correction. The linear ranges of cadmium was 0 to 10 µg/L and the analytical detection limits was 0.13 µg/L, respectively. The precision relative standard deviations was 3.82% and the spike recoveries range from 97.5% to 101.3%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.