Abstract

A simple, sensitive and selective RP-HPLC method has been developed for quantification of nodakenin in rat plasma. Nodakenin in rat plasma was extracted with acetonitrile, which also acted as a deproteinization agent. Chromatographic separation of nodakenin was performed on an analytical Diamonsil ODS C18 column, with a mobile phase of MeOH-H2O (1:1, v/v) at a flow-rate of 1.0 mL/min, and UV detection was set at 330 nm. The calibration curve was linear over the range 0.2-12.0 microg/mL (R2 = 0.9995) in rat plasma. The lower limit of detection and quantification were 0.01 and 0.1 microg/mL, respectively, using the rat plasma sample. The extraction recoveries were 77.36 +/- 4.56, 82.89 +/- 1.84 and 81.66 +/- 2.49% at concentrations of 1.0, 5.0 and 10.0 microg/mL, respectively. The intra- and inter-day precision and accuracy were validated by relative standard deviation and relative error, which were in the ranges 5.07-5.83 and 3.95-6.29%, respectively. After i.v. administration to rats at a single dose of 40 mg/kg, the plasma concentration-time curve of nodakenin was best conformed to a two-compartment open model. This assay method has been successfully applied to the study of the pharmacokinetics of nodakenin in rats.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call