Abstract

In order to meet industrial safety standards in eccentric presses, the detent force caused by the reluctance change between permanent magnet (PM) and stator teeth of the acting high force tubular permanent magnet linear synchronous machines (PMLSM) should be reduced. The detent force is generated by two components: the slot effect which is already decreased by the closing slot technique and proven in [3] and the end effect which will be optimized by using auxiliary poles at the end of the machine. Therefore a special genetic algorithm (GA) is developed which rates the simulation results of the FEM and produces new auxiliary poles. The combined simulation tries to find an optimal size and position for auxiliary poles to reduce the whole detent force. The numerical calculations propose a minimized detent force caused by the located poles, which is independent from the length of the machines (1 to 5 modules). The result will be proven by measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.