Abstract
In a recent study, we compared a new intraarterial fiberoptic "optode" probe to continuously measure arterial oxygen and carbon dioxide tensions and pH with intermittently drawn blood samples in patients undergoing surgery. In one patient with a diagnosis of Arnold-Chiari type I malformation with outflow obstruction of the fourth ventricle, a major pulmonary air embolism occurred while the patient was undergoing suboccipital craniectomy and cervical laminectomy in the prone position. Three hours after the incision the optode-displayed oxygen tension decreased from a stable value of 225 +/- 8 mm Hg to 63 mm Hg over a 10-minute period. During the same interval, carbon dioxide tension increased and end-tidal carbon dioxide decreased; shortly thereafter, transcutaneous oxygen tension decreased also. Within 20 minutes after the inspired gas mixture was changed to 100% oxygen, the patient's respiratory variables returned to near baseline. No further complications ensued. This is the first time continuously monitored arterial oxygen tension values during a pulmonary embolism have been reported. With further refinement, intraarterial optode probes will add another valuable method of detecting pulmonary air embolism.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.