Abstract
Tricresyl phosphate (TCP) in contaminated edible oils was extracted using acetonitrile and detected by thin layer chromatography as well as gas chromatography (GC). The chromatoplate was developed with isooctane-ethyl acetate (90 + 10) and visualized by spraying with 2,6-dichloroquinone chloroimide. TCP gives a characteristic blue-violet spot when heated at 100 degrees C for 15 min. The method is direct and sensitive and can be used to detect as low as 2.5 micrograms TCP or TOCP (tri-o-cresyl phosphate). GC was carried out using 10% OV-101 as the stationary phase and flame ionization detection for confirmation and quantitation of TOCP in oils.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.