Abstract

In the present research, fiber Bragg grating (FBG) sensors were applied for the detection of transverse cracks, which cause strain distribution within the gage length, in carbon fiber reinforced plastic (CFRP) cross-ply laminates. An uncoated FBG sensor was embedded in 0° ply on the border of 90° ply in a CFRP cross-ply laminate. The reflection spectra from the FBG sensor were measured at various tensile stresses. As a result, the reflection spectrum became broad and had some peaks with increase of the transverse crack density in the 90° ply. After the crack density was saturated, the spectrum became narrow and had one large peak again. For confirming that the change in the spectrum form was caused by transverse cracks, the spectra were calculated theoretically. The calculated result reproduced the change in the measured spectrum form very well. These results show that the occurrence of transverse cracks can be detected from the change in the form of the reflection spectrum, and the spectrum width at the half-maximum is a good indicator for the quantitative evaluation of the transverse crack density on real-time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.