Abstract
Hydrogenated diamond (HD) gas sensors feature an integrator-like response which occurs at room temperature and which is mediated by a thin layer of adsorbed water on the HD surface. In the present work a HD gas sensor had been exposed to randomly varying acid vapour concentrations to assess its potential in a practical gas monitoring situation. Our results demonstrate that the time-differentiated sensor output signal yields a detailed temporal image of the random vapour pulses with a time resolution in the order of 1s. In contrast, the sensor signal itself provides a measure of the total vapour concentration that had been interacting with the HD sensor surface up to the point of sensor interrogation. Large accumulated vapour concentrations lead to sensor saturation. It is further demonstrated that saturated HD sensors can be repeatedly reset into a reproducible initial condition, simply by replacing the contaminated water adsorbate layer by a fresh one.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.