Abstract

We have previously reported the isolation and testing of a DNA probe specific for the detection of Plasmodium falciparum. Field studies to compare the sensitivity and specificity of the DNA probe with that of light microscopy have been performed. In 2 studies in Thailand, 1,397 patients were tested. Microscope slides were prepared in a standard fashion and examined by clinical technicians and expert microscopists. The DNA probe method compares favorably in sensitivity with routine microscopy, detecting parasite densities as low as 40 parasites/microliters blood in the first study and, after modifications, 20-25 parasites/microliters blood in the second. Modifications included the elimination of salt from the lysis buffer, increasing the pH of the lysis buffer, and use of nylon based hybridization membranes instead of nitrocellulose. The DNA probe method offers the advantage of a standardized procedure that can be used in a batchwise fashion on a large number of samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.