Abstract
In this paper, the possibility of using monofractal and multifractal analysis of acoustic signals of pipelines to detect leaks is considered. An experimental stand has been created to study the fractal characteristics of acoustic signals of pipelines with “slit” type defects. During the experiments, defects of the “slit” type pipeline with dimensions of 2 mm, 8 mm, and 20 mm were modeled. Detrended fluctuation analysis (DFA) and the multifractal detrended fluctuation analysis (MF-DFA) were used. As a result of the experimental studies, it was found that the occurrence of leakage leads to the occurrence of anticorrelated vibrations in a pipeline with multifractal properties. The analyses of acoustic signals by DFA and MF-DFA methods make it possible to reliably determine the leakage. The Hurst exponent and the width of the multifractal spectrum can serve as indicators of the occurrence of leaks in pipelines.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.