Abstract

To date, there is an increased risk to public health and the environment due to the presence of pharmaceutically active compounds within drinking water supply and distribution networks. Owing to this, a direct injection-HPLC/MS-MS method was developed for the simultaneous determination of 16 active pharmaceutical compounds in tap water samples: amoxicillin, ampicillin, cephalexin, cefotaxime, cefuroxime, ciprofloxacin, clarithromycin, clindamycin, chloramphenicol, cyproterone, erythromycin, flutamide, spironolactone, sulfamethoxazole, tamoxifen, and trimethoprim. Limits of detection (LOD) ranged from 0.2 to 6.0µg/L while quantification limits (LOQ) from 0.3 to 20µg/L. Recovery percentages were between 70 and 125%. Total analysis time was short, with all compounds being resolved in less than 2.1min. Of the 22 tap water samples collected and analyzed, the highest concentrations corresponded to amoxicillin (147µg/L) and ciprofloxacin (44µg/L). The findings could set a precedent for establishing safe levels of these compounds and increasing standards for tap water quality in this region.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.