Abstract

A membrane immunofluorescent-antibody test was developed to detect diacetyl-producing Pediococcus contaminants in brewery pitching yeast (yeast [Saccharomyces cerevisiae] slurry collected for reinoculation). Centrifugations at 11 and 5,100 x g separate yeast cells from bacteria and concentrate the bacteria, respectively. Pelleted bacteria resuspended and trapped on a black membrane filter are reacted with monoclonal antibodies specific for cell surface antigens and then with fluorescein-conjugated indicator antibodies. Whether pitching yeast is contaminated with pediococci at 0.001% is determined in less than 4 h. The sensitivity of the assay is 2 orders of magnitude below the Pediococcus detection limit of direct microscopy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.