Abstract

Thallium (Tl) 201 and technetium (Tc) 99m tetrofosmin single-photon emission CT are routinely used in the evaluation of coronary artery disease. Mediastinal tumors demonstrate Tl 201 and Tc 99m tetrofosmin uptake. We report a 56-year-old man who developed chest pain after a previously successful angioplasty and stent of the left anterior descending coronary artery. He underwent a Tl 201, Tc 99m tetrofosmin exercise study. Abnormal mediastinal activity was visualized in both the Tl 201 and Tc 99m tetrofosmin images. Subsequently, the patient underwent resection of a stage II thymoma. Unanticipated focal extracardiac accumulation during myocardial scintiscanning should lead to further investigation to exclude mediastinal tumor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call