Abstract

The authors have been developing a hybrid single-phase Bi2223 high temperature superconducting (HTS) transformer used in the AC current source with rated current of over 500A. Its primary coil is a copper coil and secondary coil is a Bi2223 HTS coil. In this paper, the authors propose a new detection method of normal transitions in the secondary coil by using the active power method and a magnetic flux detection coil attached on the inside of the secondary coil. In the proposed method, the normal transitions are detected by measuring active power dissipated in the secondary coil, and induced voltage of the magnetic flux detection coil by a primary and leakage flux of the secondary coil enables to calculate the active power dissipated in only the secondary coil. As experimental results for a hybrid single-phase Bi2223 HTS transformer, it was found that the proposed method enabled to detect the normal transitions in its secondary superconducting coil.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.