Abstract

To compare the detectability of non-palpable breast cancer in asymptomatic women by using mammography (MMG), dynamic contrast-enhanced MR imaging (DCE-MRI) and unenhanced MR imaging with combined diffusion-weighted and T2-weighted images (DWI+T2WI). Forty-two lesions in 42 patients with non-palpable breast cancer in asymptomatic women were enrolled. For the reading test, we prepared a control including 13 normal and 8 benign cases. Each imaging set included biplane MMG, DCE-MRI and DWI+T2WI. Five readers were asked to rate the images on a scale of 0 to 100 for the likelihood of the presence of cancer and the BI-RADS category. Confidence level results were used to construct receiver operating characteristic analysis. Sensitivity and specificity were calculated for each technique. DWI+T2WI showed higher observer performances (area under the curve, AUC, 0.73) and sensitivity (50%) for the detection of non-palpable breast cancer than MMG alone (AUC 0.64; sensitivity 40%) but lower than those of DCE-MRI (AUC 0.93; sensitivity 86%). A combination of MMG and DWI+T2WI exhibited higher sensitivity (69%) compared with that of MMG alone (40%). DWI+T2WI could be useful in screening breast cancer for patients who cannot receive contrast medium and could be used as a new screening technique for breast cancer.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call