Abstract

A coamplification PCR test for the direct detection of Neisseria gonorrhoeae and Chlamydia trachomatis in urethral and endocervical swabs and urine samples from men and women was compared to standard culture techniques. Processed specimens were amplified in single reaction tubes containing primers for both organisms, and PCR products were detected by a colorimetric microwell plate hybridization assay specific for each pathogen. Of 344 specimens from men, 45 (13.1%) urine specimens were PCR positive for C. trachomatis, 51 (14.8%) urethral swab specimens were PCR positive, and 29 urethral swab specimens (8.4%) were culture positive. After analysis of discrepancies, the resolved sensitivity and specificity of PCR for C. trachomatis were 96.2 and 99.3%, respectively, in urethral swab specimens, compared to 88.2 and 98.6% for urine specimens. Of the 192 specimens from women, 28 (14.6%) urine specimens were PCR positive for C. trachomatis, 32 (16.7%) endocervical specimens were PCR positive, and 19 (9.9%) endocervical specimens were culture positive. After analysis of discrepancies, the resolved sensitivity and specificity of PCR for C. trachomatis for endocervical specimens were both 100% compared to 100 and 99.4%, respectively, for urine specimens from women. In men, 68 (19.8%) urine specimens were PCR positive for N. gonorrhoeae, 73 (21.2%) urethral swabs were PCR positive, and 59 (17.2%) urethral swabs were culture positive. After analysis of discrepancies, the resolved sensitivity and specificity of PCR for N. gonorrhoeae were 97.3 and 97.0%, respectively, for urethral specimens compared to 94.4 and 98.5% for urine specimens. In women, 18 (9.4%) urine specimens were PCR positive for N. gonorrhoeae, 23 (12.0%) were endocervical swab PCR positive, and 15 (7.8%) endocervical specimens were culture positive. After analysis of discrepancies, the resolved sensitivity and specificity of PCR for N. gonorrhoeae were 100 and 99.4%, respectively, for endocervical specimens compared to 90.0 and 95.9% for female urine specimens. These results indicate that a multiplex PCR is highly sensitive for detecting both C. trachomatis and N. gonorrhoeae from a single urine or genital swab, providing a more cost-effective way of screening multiple pathogens.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.