Abstract
An X-ray mine imaging system (XMIS) that uses a new form of backscatter x-ray radiography developed at the University of Florida was successfully field-tested at Fort A.P. Hill, Virginia in October, 2001. The XMIS obtained high quality images of both anti-tank and anti-personnel mines on several of the Fort A.P. Hill test lanes. For high resolution imaging at a power level of 750 watts, total time for scanning and for processed image acquisition was about 60 s for a 0.5 x 0.5 m area. The very good imaging results obtained from the initial field tests with the XMIS demonstrate the excellent capabilities of this system as a confirmation sensor for land mine detection. Critical to the success of the XMIS is the use of both collimated and uncollimated detectors. This yields system capabilities and performance that cannot be matched by using only uncollimated detectors with coded apertures and spatial filters to deconvolve system response. The initial field tests showed that some fairly simple modifications could significantly improve the performance of the XMIS. With the modifications, high resolution scanning of a 0.5 x 0.5 m area can be done in 20 to 30 seconds at a power level of around 300 watts.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.