Abstract
ObjectivesThe goal of this study was to evaluate the diagnostic performance of a comprehensive, multicomponent cardiac magnetic resonance (CMR) study for assessment of left atrial (LA) and left atrial appendage (LAA) thrombus. BackgroundPre-operative evaluation for pulmonary vein isolation (PVI) typically requires tomographic imaging to define pulmonary venous anatomy and transesophageal echocardiogram (TEE) to assess for the presence of LA/LAA thrombus. CMR is increasingly being used to define pulmonary venous anatomy before PVI. Limited data are available on the utility of a multicomponent CMR protocol in assessing LA/LAA thrombus. MethodsWe studied patients who underwent multicomponent CMR for evaluation of pulmonary venous anatomy before PVI and underwent TEE within 7 days. LA and LAA thrombi were evaluated by using CMR as follows: 1) cine-CMR; 2) contrast-enhanced magnetic resonance angiography; and 3) equilibrium phase delayed enhancement (DE) CMR with a long inversion time (TI) of 600 ms (long TI DE-CMR). Components of the CMR study were evaluated for diagnostic performance for detection of LA or LAA thrombus using TEE as the reference standard. ResultsDuring the study period, 261 patients were assessed. The median CHA2DS2VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, stroke/transient ischemic attack, vascular disease, age 65 to 74 years, sex category) score was 2, and 73.6% of patients were undergoing anticoagulation therapy. CMR and TEE were performed within 1.3 ± 2.3 days. LA/LAA thrombi were discovered in 9 patients (3.5%) by using TEE. Among the CMR techniques performed, long TI DE-CMR had the highest diagnostic accuracy (99.2%), sensitivity (100%), and specificity (99.2%), followed by contrast-enhanced magnetic resonance angiography (accuracy 94.3%; sensitivity 66.7%; and specificity 95.2%) and cine-CMR (accuracy 91.6%; sensitivity 66.7%; and specificity 92.5%). ConclusionsIn patients referred for PVI, CMR could be a single complete diagnostic study for assessment of pulmonary venous anatomy as well as presence of LA/LAA thrombi, thus reducing the number of pre-operative tests before PVI. Long TI DE-CMR has the best diagnostic performance and should be used for the detection of LA/LAA thrombi.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.