Abstract

The aqueous solution with iron nanoparticles investigated by a microwave stripline sensor based on the optimized double quadratic-shape design. Due to real-time near-field electromagnetic interaction between microwaves and sample S11 reflection coefficient of the sensor was changed depending on iron nanoparticles concentration in the aqueous solution at resonant frequencies. In this work we examined the iron nanoparticles concentration in the 0–20 µg/L concentration range at an operating frequency of about 1.7 GHz. The measured minimum detectable signal was 0.035 dB/(µg/L) and 0.25 MHz/(µg/L) and the measured minimum detectable concentration was 1.4 µg/L and 0.2 µg/L, respectively. The microwave response of sensor systems can be explained by the additional structural changes of water clusters due to the metal nanoparticles ablation. This implemented method has approachable development process and the accuracy of measurement is high, thus it can be applied as a physiochemical sensor for non-invasive monitoring of metal nanoparticles in complex liquids.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.