Objectives: The purpose of this study was to identify the impurities and their amounts in the fluconazole bulk drug and capsule FLUNACTM (150 mg). Method: HPLC with diode array detector was used to carry out the study. The composition of mobile phase was acetonitrile: water (85:15 %) with flow rate of 0.7 mL/min and detected at 260 ± 1 nm. Results: Two impurities (one is known impurity A and other unknown impurity) were detected in the bulk drug and also in capsule FLUNAC (150mg). The total amount of impurities in fluconazole bulk drug and capsule were 0.368% and 0.392% respectively. Conclusion: The total amount of impurities was less than 1% which is acceptable.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.