Abstract
Enhanced machine reliability through monitoring of its state of health is an emerging field of research. Ingress of contaminants such as moisture can effect electrical machine state of health and contribute to failure in winding insulation. This paper demonstrates the application of an online insulation health monitoring method to study the effect of moisture ingress on ground-wall insulation through practical experiment. The method, based on real-time high-frequency leakage current measurement, is implemented on a 2.83 kW machine during operation in open-loop configuration. The results are presented and discussed, demonstrating the feasibility of diagnosis of moisture ingress.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.