Abstract

International standard bodies have specified an instrument capable of detecting and assessing the severity of lighting flicker, which is called a flickermeter. However, a deficiency with regard to flicker caused by high-frequency interharmonics has been reported in the recent literature. In this paper, another deficiency of the International Electrotechnical Commission (IEC) flickermeter with regard to low-frequency interharmonics, whose frequencies are below the difference between the fundamental frequency and the cutoff frequency of a bandpass filter of the IEC standard flickermeter, will be discussed and illustrated based on analysis and numerical experiments. A new approach based on down-up sampling in the discrete-time sample domain is also proposed to address the flicker-detection problem associated with interharmonics. We demonstrate the efficacy of the proposed method by a comparison with the current flickermeter standard in the presence of interharmonics.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.